Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Thorac Cardiovasc Surg ; 167(1): e6-e21, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37211245

RESUMO

OBJECTIVE: Mitochondrial transplantation has been shown to preserve myocardial function and viability in adult porcine hearts donated after circulatory death (DCD) . Herein, we investigate the efficacy of mitochondrial transplantation for the preservation of myocardial function and viability in neonatal and pediatric porcine DCD heart donation. METHODS: Circulatory death was induced in neonatal and pediatric Yorkshire pigs by cessation of mechanical ventilation. Hearts underwent 20 or 36 minutes of warm ischemia time (WIT), 10 minutes of cold cardioplegic arrest, and then were harvested for ex situ heart perfusion (ESHP). Following 15 minutes of ESHP, hearts received either vehicle (VEH) or vehicle containing isolated autologous mitochondria (MITO). A sham nonischemic group (SHAM) did not undergo WIT, mimicking donation after brain death heart procurement. Hearts underwent 2 hours each of unloaded and loaded ESHP perfusion. RESULTS: Following 4 hours of ESHP perfusion, left ventricle developed pressure, dP/dt max, and fractional shortening were significantly decreased (P < .001) in DCD hearts receiving VEH compared with SHAM hearts. In contrast, DCD hearts receiving MITO exhibited significantly preserved left ventricle developed pressure, dP/dt max, and fractional shortening (P < .001 each vs VEH, not significant vs SHAM). Infarct size was significantly decreased in DCD hearts receiving MITO as compared with VEH (P < .001). Pediatric DCD hearts subjected to extended WIT demonstrated significantly preserved fractional shortening and significantly decreased infarct size with MITO (P < .01 each vs VEH). CONCLUSIONS: Mitochondrial transplantation in neonatal and pediatric pig DCD heart donation significantly enhances the preservation of myocardial function and viability and mitigates against damage secondary to extended WIT.


Assuntos
Transplante de Coração , Humanos , Adulto , Criança , Recém-Nascido , Suínos , Animais , Transplante de Coração/efeitos adversos , Coração , Miocárdio , Morte Encefálica , Perfusão , Infarto , Doadores de Tecidos
3.
4.
J Extra Corpor Technol ; 54(1): 42-49, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36380826

RESUMO

Thromboelastography (TEG) can predict bleeding in pediatric patients undergoing cardiac surgery. We hypothesized that results obtained from TEG®5000 correlate with the new point-of-care TEG®6S system and that TEG®6S rewarming maximum amplitude (MA) is associated with surrogate endpoints for perioperative bleeding in pediatric patients who underwent complex cardiac surgery. We describe a retrospective study of pediatric (≤18 years) patients who underwent complex cardiac surgery on cardiopulmonary bypass. Citrate whole-blood samples were used to compared TEG®5000 vs.TEG®6S and TEG®6S-FLEV (with fibrinogen measurement) vs. Clauss-fibrinogen methods. TEG®6S parameters obtained during rewarming were compared to the surrogate endpoints for perioperative bleeding using linear regression analysis. Among 100 patients, 225 TEG®5000 vs.TEG®6S comparisons and 54 TEG®6S-FLEV were analyzed. Good correlation was observed for all parameters comparing TEG®5000 to TEG®6S and TEG®6S-FLEV to the Clauss-fibrinogen method (Pearson r ≥ .7). Similar to rewarming TEG®5000 MA, rewarming TEG®6S MA was the only parameter independently associated with risk for perioperative bleeding (median [interquartile range {IQR}] in bleeding vs. nonbleeding patients: 35 [29, 48] vs. 37 [32, 55]; p = .02). A platelet transfusion calculator was developed based on TEG®6S results by determining the relationship between platelet transfusion volume (mL/kg) and percent change in MA using linear regression analysis. TEG®6S is a good alternative point-of-care method to analyze a patient's coagulation profile and it is comparable to TEG®5000 in pediatric patients undergoing cardiac surgery on cardiopulmonary bypass. Lower TEG®6S MA during rewarming is associated with increased risk for perioperative bleeding. TEG analysis during rewarming may be useful in customizing platelet transfusion therapy by reducing the risk of bleeding while minimizing excessive blood product transfusions.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tromboelastografia , Humanos , Criança , Tromboelastografia/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Retrospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fibrinogênio/uso terapêutico , Fibrinogênio/análise
5.
J Extra Corpor Technol ; 54(4): 291-317, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36742024

RESUMO

The conduct of cardiopulmonary bypass in neonatal, infant, and pediatric patients continuously evolves as new devices and innovative techniques are introduced. Since 1989, periodic pediatric perfusion surveys have been conducted to ascertain practice patterns involving demographics, equipment, and perfusion techniques. The goal of this current project is to provide an updated perspective on international pediatric and congenital perfusion practice since the last survey conducted in 2016. In July 2021, a 100-question perfusion survey was distributed to 284 pediatric cardiac surgery centers using a secure web browser-based data application. Each center was given a unique survey hyperlink to ensure one response per institution and to monitor the response rate. Centers were given 1 month to complete the survey and electronic reminders were sent weekly to nonrespondents. After the survey was closed, information from completed surveys was exported to a software program for analysis. Responses were received from 153 of 284 pediatric centers for a response rate of 54%. Sixty respondents (39%) were from North American (NA) centers while 93 respondents (61%) were from non-North American (NNA) centers. The vast majority of centers use a roller head arterial pump (93%), hollow fiber oxygenators with open reservoirs (86%), and integrated arterial line filters (73%). The use of modified ultrafiltration was reported by 76% of centers. Ninety-two percent of centers reported the use of selective antegrade cerebral perfusion for aortic arch repairs. The N + 1 staffing model was most prevalent (52%), followed by two perfusionists per case (33%). Periodic surveys continue to be a useful modality in assessing regional variation in pediatric perfusion practice. This survey marked the first time the majority of responses came from non-North American institutions. Identifying these practice patterns may aid in the development of, and adherence to, regional standards and guidelines. This would foster the reduction of variation in practice and potentially improve patient safety.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Lactente , Recém-Nascido , Criança , Humanos , Perfusão/métodos , Inquéritos e Questionários , Ponte Cardiopulmonar/métodos , Cardiopatias Congênitas/cirurgia
6.
Perfusion ; 37(7): 684-691, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34080462

RESUMO

OBJECTIVE: The aim of this study was to evaluate outcome measures between our standard multidose cardioplegia protocol and a del Nido cardioplegia protocol in congenital heart surgery patients. METHODS: Retrospective single-center study including 250 consecutive patients that received del Nido cardioplegia (DN group) with a mandatory reperfusion period of 30% of cross clamp time and 250 patients that received a modified St. Thomas' solution (ST group). Groups were matched by age, weight, gender, and Risk Adjustment for Congenital Heart Surgery (RACHS-1) scores. Preoperative hematocrit and oxygen saturation were also recorded. Outcomes analyzed were the vasoactive inotropic score (VIS), lactate, ventilation time, ventricular dysfunction with low cardiac output syndrome (LCOS), intensive care unit (ICU) length of stay (LOS), hospital LOS, bypass and aortic cross-clamp times, and in-hospital mortality. RESULTS: Both groups were comparable demographically. Statistically significant differences (p ⩽ 0.05) were noted for cardiac dysfunction with LCOS, hematocrit at end of surgery (p = 0.0038), VIS on ICU admission and at end of surgery (p = 0.0111), and ICU LOS (p = 0.00118) with patients in the DN group having more desirable values for those parameters. Other outcome measures did not reach statistical significance. CONCLUSION: In our congenital cardiac surgery population, del Nido cardioplegia strategy was associated with less ventricular dysfunction with LCOS, a lower VIS and decreased ICU LOS compared with patients that received our standard myocardial protection using a modified St. Thomas' solution. Despite the limitation of this study, including its retrospective nature and cohort size, these data supported our transition to incorporate del Nido cardioplegia solution with a mandatory reperfusion period as the preferred myocardial protection method in our program.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Disfunção Ventricular , Brasil , Baixo Débito Cardíaco , Soluções Cardioplégicas/uso terapêutico , Criança , Eletrólitos , Parada Cardíaca Induzida/métodos , Cardiopatias Congênitas/cirurgia , Humanos , Lactatos , Lidocaína , Sulfato de Magnésio , Manitol , Cloreto de Potássio , Estudos Retrospectivos , Bicarbonato de Sódio , Soluções , Disfunção Ventricular/tratamento farmacológico
7.
J Extra Corpor Technol ; 53(3): 186-192, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34658410

RESUMO

A 1-year old male patient with Williams syndrome and multiple prior interventions presented for surgical repair of his descending aorta (DA) through a left thoracotomy. Concerns for significant bleeding and spinal cord protection led the care team to consider a left heart bypass (LHB) circuit with options for pump sucker use, heat exchange capacity, and the possibility of converting to traditional cardiopulmonary bypass (CPB). A traditional CPB circuit with a roller-head arterial pump was assembled with a bypass line around the cardiotomy venous reservoir (CVR). Excluding the CVR with this line allowed for a closed LHB circuit. A second pump head was integrated to both recirculate the CVR volume and to serve as a means for controlled volume administration to the closed LHB circuit. Pump sucker return directed to the CVR could easily be transfused back to the patient. The patient was placed on the hybrid LHB circuit and cooled to 32°C. DA clamps were placed. Upper body dynamic blood pressure was managed for a target mean of 50 mmHg, the left atrial pressure (LAP) was maintained in the 5-7 mmHg range, and the nonpulsatile lower body blood pressure was targeted at 40-50 mmHg. Cerebral near-infrared spectroscopy (NIRS) helped guide volume and pressure management. The surgeons placed two long-segment patches on the DA, moving clamps as needed. The patient was rewarmed and separated from the hybrid LHB circuit after 82 minutes. Closed circuit LHB can be provided with a roller-head hybrid circuit incorporating an oxygenator for gas exchange, central cooling and warming, and arterial line filtration along with a CVR for pump sucker use and controlled transfusion to the patient.


Assuntos
Derivação Cardíaca Esquerda , Síndrome de Williams , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Ponte Cardiopulmonar , Humanos , Lactente , Masculino , Oxigenadores
8.
ASAIO J ; 67(12): 1342-1348, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34415712

RESUMO

Cardiopulmonary bypass (CPB) circuits can significantly sequester intravenous anesthetics. Adsorption of medications by our institution's standard circuit (Terumo CAPIOX FX05 oxygenator; noncoated polyvinylchloride tubing) has not been described. We prepared ex vivo CPB circuits with and without oxygenators. Medication combinations studied included midazolam (0.5 mg), fentanyl (50 µg), midazolam (0.5 mg) with morphine (0.5 mg), and midazolam (0.5 mg) with fentanyl (50 µg). Medications were administered after obtaining baseline samples. Samples were drawn at 2, 5, 15, 30, 60, 120, and 180 minutes, and analyzed for concentration of injected medications. Midazolam demonstrated no sequestration after 180 minutes. Fentanyl concentration at 180 minutes was lower with an oxygenator (52.7 ± 12.5 vs. 110.9 ± 12.0 ng/ml, P = 0.00432). More fentanyl was found in solution after 180 minutes when given with midazolam compared to fentanyl given alone in the presence of an oxygenator (101 ± 22.3 vs. 52.7 ± 12.5 ng/ml, P = 0.044). Less midazolam was present after 180 minutes when given with morphine compared to midazolam given alone in the absence of an oxygenator (1264.9 ± 425.6 vs. 2124 ± 254 ng/ml, P = 0.037). We successfully characterized the adsorption of various combinations of midazolam, fentanyl, and morphine to our CPB circuit, showing that fentanyl and midazolam behave differently based on other medications present.


Assuntos
Fentanila , Midazolam , Ponte Cardiopulmonar , Morfina , Oxigenadores
10.
J Extra Corpor Technol ; 52(4): 303-313, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33343033

RESUMO

Ex situ heart perfusion (ESHP) has proven to be an important and valuable step toward better preservation of donor hearts for heart transplantation. Currently, few ESHP systems allow for a convenient functional and physiological evaluation of the heart. We sought to establish a simple system that provides functional and physiological assessment of the heart during ESHP. The ESHP circuit consists of an oxygenator, a heart-lung machine, a heater-cooler unit, an anesthesia gas blender, and a collection funnel. Female Yorkshire pig hearts (n = 10) had del Nido cardioplegia (4°C) administered, excised, and attached to the perfusion system. Hearts were perfused retrogradely into the aortic root for 2 hours before converting the system to an isovolumic mode or a working mode for further 2 hours. Blood samples were analyzed to measure metabolic parameters. During the isovolumic mode (n = 5), a balloon inserted in the left ventricular (LV) cavity was inflated so that an end-diastolic pressure of 6-8 mmHg was reached. During the working mode (n = 5), perfusion in the aortic root was redirected into left atrium (LA) using a compliance chamber which maintained an LA pressure of 6-8 mmHg. Another compliance chamber was used to provide an afterload of 40-50 mmHg. Hemodynamic and metabolic conditions remained stable and consistent for a period of 4 hours of ESHP in both isovolumic mode (LV developed pressure: 101.0 ± 3.5 vs. 99.7 ± 6.8 mmHg, p = .979, at 2 and 4 hours, respectively) and working mode (LV developed pressure: 91.0 ± 2.6 vs. 90.7 ± 2.5 mmHg, p = .942, at 2 and 4 hours, respectively). The present study proposed a novel ESHP system that enables comprehensive functional and metabolic assessment of large mammalian hearts. This system allowed for stable myocardial function for up to 4 hours of perfusion, which would offer great potential for the development of translational therapeutic protocols to improve dysfunctional donated hearts.


Assuntos
Transplante de Coração , Animais , Feminino , Coração , Humanos , Miocárdio , Perfusão , Suínos , Doadores de Tecidos
11.
J Heart Lung Transplant ; 39(11): 1279-1288, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32703639

RESUMO

BACKGROUND: Donation after circulatory death (DCD) offers an additional source of cardiac allografts, potentially allowing expansion of the donor pool, but is limited owing to the effects of ischemia. In this study, we investigated the efficacy of mitochondrial transplantation to enhance myocardial function of DCD hearts. METHODS: Circulatory death was induced in Yorkshire pigs (40-50 kg, n = 29) by a cessation of mechanical ventilation. After 20 minutes of warm ischemia, cardioplegia was administered. The hearts were then reperfused on an ex-situ blood perfusion system. After 15 minutes of reperfusion, hearts received either vehicle alone (vehicle [VEH], 10 ml; n = 8) or vehicle containing autologous mitochondria (vehicle with mitochondria as a single injection [MT], 5 × 109 in 10 ml, n = 8). Another group of hearts (serial injection of mitochondria [MTS]; n = 6) received a second injection of mitochondria (5 × 109 in 10 ml) after 2 hours of ex-situ heart perfusion and reperfused for an additional 2 hours. A Sham group (sham hearts; n = 6) did not undergo any warm ischemia. RESULTS: At the end of 4 hours of reperfusion, MT and MTS groups showed a significantly increased left ventricle/ventricular peak developed pressure (p = 0.002), maximal left ventricle/ventricular pressure rise (p < 0.001), fractional shortening (p < 0.001), and myocardial oxygen consumption (p = 0.004) compared with VEH. Infarct size was significantly decreased in MT and MTS groups compared with VEH (p < 0.001). No differences were found in arterial lactate levels among or within groups throughout reperfusion. CONCLUSIONS: Mitochondrial transplantation significantly preserves myocardial function and oxygen consumption in DCD hearts, thus providing a possible option for expanding the heart donor pool.


Assuntos
Transplante de Coração/métodos , Mitocôndrias Cardíacas/transplante , Perfusão/métodos , Doadores de Tecidos , Animais , Modelos Animais de Doenças , Feminino , Suínos
13.
J Extra Corpor Technol ; 51(4): 221-226, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31915405

RESUMO

Heparin is the primary anticoagulant used during cardiac surgery to prevent thrombosis due to cardiopulmonary bypass (CPB)-related activation of the hemostatic system. The efficacy of heparin in the operating room is generally determined by activated clotting time (ACT) point-of-care tests performed throughout the procedure. In an effort to transition to the Hemochron Elite which requires approximately 1/10th the sampling volume of blood, we conducted a prospective study in 260 pediatric patients undergoing CPB. ACT tests were performed during CPB with a total of 260 pre-bypass and 1,117 on-bypass ACT values recorded. All samples were run simultaneously on both ACT devices. Several therapeutic cut-off possibilities ranging from >380 to >480 seconds were evaluated to ascertain the ACT level on the Elite device which best correlated with results from the Response device. Linear regression was used to determine correlation. The correlation between the two methods was moderate with a Pearson r of .6 and .4 for pre-bypass bolus ACT values and on-bypass ACT values, respectively. As the therapeutic ACT cut-off values were lowered from 480 to 380 seconds on the Elite device relative to the Response device (>480 seconds) for the on-bypass heparin samples, more patients would be under-dosed (incidence rising from 1 to 2%) and fewer patients would be overdosed (incidence decreasing from 32 to 5%) and the percent correlation between devices increased from 67 to 93%. A similar trend was observed with the pre-bypass heparin bolus samples. There was no significant effect of temperature on the ACT values comparing both devices. A therapeutic ACT value of >400 seconds for CPB with the Hemochron Elite device reasonably approximates a therapeutic ACT value of >480 seconds on the Hemochron Response device in our congenital cardiac surgery practice. Transitioning to the Elite device significantly reduces the overall sampling volume required for ACT monitoring during cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Anticoagulantes , Ponte Cardiopulmonar , Heparina , Humanos , Estudos Prospectivos , Tempo de Coagulação do Sangue Total
14.
Perfusion ; 33(8): 667-678, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29963965

RESUMO

Hypoplastic left heart syndrome (HLHS) is a rare and severe congenital cardiac defect. Approximately 1000 infants are born with HLHS in the United States every year. Healthcare collaboratives over the last decade have focused on sharing patient experiences and techniques in an effort to improve outcomes. In 2010, cardiologists and patient families joined together to improve the care of HLHS patients by forming the National Pediatric Cardiology Quality Improvement Collaborative (NPC-QIC). Sixty-six of the approximately 110 institutions caring for patients with HLHS in the United States and Canada are now members of NPC-QIC. In 2017, cardiovascular perfusionists joined the collaborative as another specialty involved in the care of HLHS patients. Perfusionists and cardiac surgeons developed the collaborative's first conduct of perfusion survey for the Norwood Stage 1 procedure, specifically targeting the provision of cardiopulmonary bypass for patients with HLHS. This manuscript discusses the results of this survey, unveiling a significant variance in the conduct of perfusion for this patient population.


Assuntos
Ponte Cardiopulmonar , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Procedimentos de Norwood , Qualidade da Assistência à Saúde , Canadá/epidemiologia , Feminino , Humanos , Síndrome do Coração Esquerdo Hipoplásico/epidemiologia , Recém-Nascido , Masculino , Estados Unidos/epidemiologia
15.
Braz J Cardiovasc Surg ; 33(3): 224-232, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30043914

RESUMO

OBJECTIVE: Hemodilution is a concern in cardiopulmonary bypass (CPB). Using a smaller dual tubing rather than a single larger inner diameter (ID) tubing in the venous limb to decrease prime volume has been a standard practice. The purpose of this study is to evaluate these tubing options. METHODS: Four different CPB circuits primed with blood (hematocrit 30%) were investigated. Two setups were used with two circuits for each one. In Setup I, a neonatal oxygenator was connected to dual 3/16" ID venous limbs (Circuit A) or to a single 1/4" ID venous limb (Circuit B); and in Setup II, a pediatric oxygenator was connected to dual 1/4" ID venous limbs (Circuit C) or a single 3/8" ID venous limb (Circuit D). Trials were conducted at arterial flow rates of 500 ml/min up to 1500 ml/min (Setup I) and up to 3000 ml/min (Setup II), at 36°C and 28°C. RESULTS: Circuit B exhibited a higher venous flow rate than Circuit A, and Circuit D exhibited a higher venous flow rate than Circuit C, at both temperatures. Flow resistance was significantly higher in Circuits A and C than in Circuits B (P<0.001) and D (P<0.001), respectively. CONCLUSION: A single 1/4" venous limb is better than dual 3/16" venous limbs at all flow rates, up to 1500 ml/min. Moreover, a single 3/8" venous limb is better than dual 1/4" venous limbs, up to 3000 ml/min. Our findings strongly suggest a revision of perfusion practice to include single venous limb circuits for CPB.


Assuntos
Cânula/normas , Ponte Cardiopulmonar/instrumentação , Oxigenadores/normas , Velocidade do Fluxo Sanguíneo/fisiologia , Ponte Cardiopulmonar/métodos , Desenho de Equipamento , Segurança de Equipamentos , Hemodiluição , Humanos , Modelos Cardiovasculares , Pediatria/instrumentação , Padrões de Referência , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo , Pressão Venosa/fisiologia
16.
Rev. bras. cir. cardiovasc ; 33(3): 224-232, May-June 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-958406

RESUMO

Abstract Objective: Hemodilution is a concern in cardiopulmonary bypass (CPB). Using a smaller dual tubing rather than a single larger inner diameter (ID) tubing in the venous limb to decrease prime volume has been a standard practice. The purpose of this study is to evaluate these tubing options. Methods: Four different CPB circuits primed with blood (hematocrit 30%) were investigated. Two setups were used with two circuits for each one. In Setup I, a neonatal oxygenator was connected to dual 3/16" ID venous limbs (Circuit A) or to a single 1/4" ID venous limb (Circuit B); and in Setup II, a pediatric oxygenator was connected to dual 1/4" ID venous limbs (Circuit C) or a single 3/8" ID venous limb (Circuit D). Trials were conducted at arterial flow rates of 500 ml/min up to 1500 ml/min (Setup I) and up to 3000 ml/min (Setup II), at 36°C and 28°C. Results: Circuit B exhibited a higher venous flow rate than Circuit A, and Circuit D exhibited a higher venous flow rate than Circuit C, at both temperatures. Flow resistance was significantly higher in Circuits A and C than in Circuits B (P<0.001) and D (P<0.001), respectively. Conclusion: A single 1/4" venous limb is better than dual 3/16" venous limbs at all flow rates, up to 1500 ml/min. Moreover, a single 3/8" venous limb is better than dual 1/4" venous limbs, up to 3000 ml/min. Our findings strongly suggest a revision of perfusion practice to include single venous limb circuits for CPB.


Assuntos
Humanos , Oxigenadores/normas , Ponte Cardiopulmonar/instrumentação , Cânula/normas , Pediatria/instrumentação , Padrões de Referência , Temperatura , Fatores de Tempo , Pressão Venosa/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Ponte Cardiopulmonar/métodos , Reprodutibilidade dos Testes , Desenho de Equipamento , Segurança de Equipamentos , Hemodiluição , Modelos Cardiovasculares
17.
J Thorac Cardiovasc Surg ; 156(1): 318-324, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29615331

RESUMO

OBJECTIVE: Oxygenators for cardiopulmonary bypass require water flow for their integral heat exchanger. Heater-cooler units are nearly universally used for this requirement. Heater-cooler units pose the risk of aerosolized infection. The Centers for Disease Control and Prevention recommended discontinuing use of Stöckert 3T heater-cooler units (LivaNova PLC, London, United Kingdom) in October 2016 because of this risk. We aimed to reduce the risk of aerosolized infection posed by heater-cooler units by eliminating those devices from our operating rooms. METHODS: The cardiac surgery division collaborated with in-house specialties to engineer a novel wall water system. The design called for service to 4 operating rooms with the actual water mixing valve in an operating room closet. Remote temperature control was mounted next to the heart-lung machine. Primary safety systems built into the water system include 5 µm filtration, pressure regulating and relief valves, flow quantifiers, limits to the hot and chilled input temperatures, and a novel bridge near the heart-lung machine that allows the perfusionist to test the system before patient use and to quickly disconnect the patient in case of system malfunction. In addition, all water line connections can be made with the tubing drained and never under pressure. RESULTS: This novel wall water system has successfully provided heat exchanger water flow on 625 patients undergoing congenital heart surgery requiring cardiopulmonary bypass during its first 9 months of use. CONCLUSIONS: Wall water systems are an option for oxygenator heat exchangers that allow for improved heat exchange performance while reducing the risk of heater-cooler unit-associated infection during cardiac surgery.


Assuntos
Ponte Cardiopulmonar/instrumentação , Infecção Hospitalar/prevenção & controle , Contaminação de Equipamentos/prevenção & controle , Máquina Coração-Pulmão/microbiologia , Calefação/instrumentação , Salas Cirúrgicas , Oxigenadores/microbiologia , Microbiologia da Água , Abastecimento de Água , Aerossóis , Ponte Cardiopulmonar/efeitos adversos , Infecção Hospitalar/microbiologia , Infecção Hospitalar/transmissão , Desenho de Equipamento , Máquina Coração-Pulmão/efeitos adversos , Teste de Materiais , Fatores de Risco
18.
Perfusion ; 33(7): 525-532, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29638202

RESUMO

INTRODUCTION: Comparison of two pediatric cases at our institution that utilized bivalirudin for anticoagulation on cardiopulmonary bypass (CPB); a bilateral lung transplant (BLT) and a ventricular assist device (VAD) implantation. METHODS: The same bivalirudin protocol was utilized in both cases with an initial bolus of 1 mg/kg administered by the anesthesia team, a 50 mg bolus in the pump prime at the time of the initial patient bolus and an initial infusion rate of 2.5 mg/kg/h, with titration as needed during CPB to maintain kaolin-activated clotting time (K-ACT) values >400 s. RESULTS: The BLT experienced high K-ACT levels (>720 s) for the majority of the case despite decreasing the bivalirudin infusion rate to 0.5 mg/kg/h. The VAD implantation case required the bivalirudin infusion rate to be increased to 5.0 mg/kg/h throughout the case due to low K-ACTs. CONCLUSION: The literature strongly supports a specific infusion rate1-7 (2.5 mg/kg/h) for bivalirudin anticoagulation during extracorporeal circulation. Clinicians must consider the loss of clotting factors and the administration of blood products while adjusting the bivalirudin infusion during bypass. We have now elected to maintain an infusion rate of ≥0.5 mg/kg/h for bivalirudin anticoagulation at our center, based on institutional experience, though consideration for a higher infusion rate for an added margin of safety should be considered. It is imperative to have a well-developed protocol for the management of these cardiopulmonary bypass patients and we offer our one-page timeline of events to help guide other pediatric centers looking to use bivalirudin anticoagulation.


Assuntos
Antitrombinas/uso terapêutico , Ponte Cardiopulmonar/métodos , Fragmentos de Peptídeos/uso terapêutico , Adolescente , Antitrombinas/farmacologia , Criança , Feminino , Hirudinas/farmacologia , Humanos , Masculino , Fragmentos de Peptídeos/farmacologia , Proteínas Recombinantes/farmacologia , Proteínas Recombinantes/uso terapêutico
19.
Paediatr Anaesth ; 28(5): 450-457, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29575610

RESUMO

BACKGROUND: Blood transfusion has well-documented adverse effects. As part of a blood conservation initiative at our center, we began routine use of cell saver for all congenital heart surgery performed on cardiopulmonary bypass since 2014. AIMS: This study aimed to compare transfusion rates prior to, and in the first and second year after this initiative. We hypothesized that cell saver use would decrease transfusion requirements in second year after use of the cell saver compared to the pre cell saver group. METHODS: Consecutive patients under 18 years undergoing congenital heart surgery on cardiopulmonary bypass were retrospectively analyzed as 3 one-year cohorts defined above. We excluded patients who required mechanical support or reoperation at index admission. Baseline characteristics, and use of blood intraoperatively and postoperatively were compared between groups. RESULTS: The 3 groups had similar baseline characteristics. Blood use was significantly lower in year 2 after cell saver initiation as compared to the pre cell saver group both intra- and postoperatively. The median difference in volume of intraoperative blood transfusion was lower by 138 mL/m2 (-266, -10 mL/m2 ) in year 2 when compared to the pre cell saver group. Similarly, the proportion of subjects requiring red blood cell transfusion postoperatively on day of surgery was lower by 10% (-15%, -6%). CONCLUSION: Standardized use of cell saver significantly decreased perioperative blood use in children undergoing cardiac surgery at our center. A risk-adjusted transfusion threshold for children undergoing heart surgery needs to be developed to further decrease exposure to blood products and associated costs.


Assuntos
Preservação de Sangue/métodos , Transfusão de Sangue Autóloga/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Transfusão de Eritrócitos/métodos , Eritrócitos , Cardiopatias Congênitas/cirurgia , Adolescente , Perda Sanguínea Cirúrgica , Ponte Cardiopulmonar/métodos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Período Pós-Operatório , Estudos Retrospectivos , Albumina Sérica Humana/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...